More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280L230801R2101 287.00 57.69 40.01 GP-PC200 BMS
GPHC280H240413R1001 295.00 56.97 41.03 GP-PC200 BMS
GPHC280H240605R2902 295.00 57.12 40.95 GP-PC200 BMS
GPEV280H240611R1004 305.00 57.99 40.44 GP-PC200 BMS
GPEV280H240520R1007 304.00 58.00 42.71 GP-PC200 BMS
GPHC280H240604R1001 295.00 56.97 41.38 GP-PC200 BMS
GPHC280H240710R1203 295.00 56.64 41.37 GP-PC200 BMS
GPHC280H240822R1001 294.00 57.17 43.98 GP-JK200 BMS
GPHC280H240820R1002 296.00 57.01 40.91 GP-PC200 BMS
GPHC280H240506R2904 293.00 56.41 41.94 GP-PC200 BMS
GPEV280H240323R1013 296.00 57.95 44.19 GP-PC200 BMS
GPEV280H240620R1030 304.00 57.26 41.22 GP-PC200 BMS
GPEV280H240520R1018 300.00 57.90 42.45 GP-PC200 BMS
GPEV280H231204R1006 304.00 58.00 43.11 GP-PC200 BMS
GPRP280L231012R1015 290.00 57.52 40.07 GP-PC200 BMS
GPEV280H240710R1012 302.00 57.99 42.21 GP-PC200 BMS
GPHC280H240422R1206 294.00 57.67 41.77 GP-JK200 BMS
GPHC280H240822R1304 295.00 57.02 42.11 GP-PC200 BMS
GPRP280L240304R3202 284.00 57.50 41.70 GP-PC200 BMS
GPEV280H240729R1005 303.00 58.00 41.67 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H240905R1020
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: RN200
Balancer Type: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.45 V
Min Discharge Voltage: 42.68 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPEV280H240905R1020 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 1 04QCB76G47703JE6W0005188 314.62 2,788.0 2,781.9 3,297.3 0.1543 0.1545 0.1516 71.81 2024-07-29
2 14 04QCB76G27603JE6L0010708 314.55 2,799.8 2,792.6 3,297.1 0.1565 0.1555 0.1501 71.60 2024-07-29
3 15 04QCB76G26903JE6P0004676 314.51 2,792.4 2,787.7 3,297.3 0.1561 0.1572 0.1541 72.37 2024-07-29
4 41 04QCB76G40603JE6N0001653 314.54 2,785.0 2,781.3 3,297.4 0.1564 0.1565 0.1554 71.65 2024-07-29
5 75 04QCB76G27103JE6T0009380 314.63 2,789.8 2,783.5 3,297.4 0.1563 0.1573 0.1537 71.60 2024-07-29
6 77 04QCB76G26703JE6Y0002473 314.65 2,794.8 2,791.3 3,297.4 0.1571 0.1570 0.1540 71.60 2024-07-29
7 79 04QCB76G47503JE6V0004796 314.65 2,794.1 2,791.0 3,297.6 0.1510 0.1540 0.1505 71.75 2024-07-29
8 90 04QCB76G27003JE6R0007317 314.60 2,792.7 2,787.9 3,297.4 0.1560 0.1563 0.1534 72.00 2024-07-29
9 106 04QCB76G27203JE6E0003913 314.62 2,797.5 2,794.6 3,297.3 0.1567 0.1570 0.1553 71.65 2024-07-29
10 131 04QCB76G51303JE6T0006223 314.65 2,789.8 2,788.1 3,298.1 0.1530 0.1549 0.1513 71.72 2024-07-29
11 171 04QCB76G25603JE660011481 314.62 2,803.8 2,802.7 3,297.2 0.1549 0.1566 0.1534 72.88 2024-07-29
12 184 04QCB76G54203JE750008442 314.49 2,799.0 2,792.3 3,297.8 0.1542 0.1552 0.1533 71.75 2024-07-29
13 192 04QCB76G27203JE6T0002727 314.63 2,786.6 2,782.1 3,297.6 0.1569 0.1586 0.1535 71.58 2024-07-29
14 243 04QCB76G26503JE6X0009700 314.58 2,797.4 2,791.4 3,297.5 0.1569 0.1556 0.1538 72.27 2024-07-29
15 273 04QCB76G27203JE6T0005107 314.53 2,787.3 2,783.3 3,297.4 0.1575 0.1561 0.1550 71.57 2024-07-29
16 277 04QCB76G27203JE6T0004433 314.49 2,787.0 2,783.4 3,297.5 0.1560 0.1547 0.1531 72.23 2024-07-29
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup