Flash Sale For USA DiySolarForum Users! >> Click to Check >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPHC280H240401R1004 294.00 57.45 41.60 GP-PC200 BMS
GPEV280H230625R1008 304.00 57.28 41.32 GP-PC200 BMS
GPEV280H240314R1009 301.00 58.00 44.22 GP-RN200 BMS
GPEV280L230801R2405 289.00 57.41 40.28 GP-PC200 BMS
GPEV280H240115R1003 303.00 58.00 42.09 GP-PC200 BMS
GPEV280H230625R1039 304.00 56.81 42.79 GP-PC200 BMS
GPEV280H240122R1006 299.00 57.99 42.73 GP-PC200 BMS
GPEV280L230913R2905 281.00 57.71 41.78 GP-RN150 BMS
GPRP280L231127R2602 286.00 57.98 40.70 GP-PC200 BMS
GPEV280L230801R2403 289.00 57.47 40.08 GP-PC200 BMS
GPEV280H240401R1031 303.00 57.99 42.67 GP-PC200 BMS
GPEV280L230801R2401 288.00 56.84 40.37 GP-PC200 BMS
GPEV280H231123R1008 303.00 57.65 41.65 GP-PC200 BMS
GPEV280H240323R1014 305.00 57.99 42.48 GP-PC200 BMS
GPHC280H240413R1301 294.00 56.97 41.62 GP-PC200 BMS
GPRP280L231107R3201 284.00 56.26 42.91 GP-PC200 BMS
GPEV280H231019R1010 301.00 57.67 41.67 GP-PC200 BMS
GPHC280H240422R1203 294.00 56.69 42.78 GP-JK200 BMS
GPRP280L231212R5002 283.00 57.12 41.15 GP-PC200 BMS
GPRP280L231212R2202 283.00 57.60 41.72 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230625R1022
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: With Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.57 V
Min Discharge Voltage: 40.76 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 22 04QCB76G55503JD5F0000113 314.84 2,801.6 2,792.3 3,297.3 0.1558 0.1564 0.1569 71.55 2023-06-08
2 68 04QCB76G52203JD5F0002184 314.81 2,798.8 2,789.1 3,297.3 0.1533 0.1530 0.1515 71.52 2023-06-09
3 160 04QCB76G55703JD5G0001997 314.85 2,800.0 2,793.3 3,297.4 0.1538 0.1582 0.1586 71.49 2023-06-08
4 210 04QCB76G52503JD5F0001226 314.84 2,800.0 2,792.2 3,297.4 0.1556 0.1561 0.1574 71.71 2023-06-08
5 214 04QCB76G55703JD5G0004986 314.81 2,798.5 2,792.7 3,297.6 0.1548 0.1548 0.1579 71.49 2023-06-08
6 222 04QCB76G55703JD5G0000982 314.86 2,802.8 2,796.5 3,297.5 0.1562 0.1549 0.1567 71.49 2023-06-08
7 223 04QCB76G52503JD5F0000609 314.86 2,802.2 2,794.9 3,297.5 0.1541 0.1532 0.1574 71.52 2023-06-08
8 251 04QCB76G55703JD5G0001744 314.83 2,798.1 2,789.9 3,297.6 0.1567 0.1562 0.1562 71.48 2023-06-08
9 282 04QCB76G55703JD5G0003226 314.85 2,800.6 2,794.9 3,297.6 0.1567 0.1578 0.1565 71.51 2023-06-08
10 333 04QCB76G52503JD5F0003612 314.85 2,799.7 2,791.1 3,297.3 0.1550 0.1544 0.1558 71.58 2023-06-08
11 361 04QCB76G59403JD5H0002323 314.82 2,804.3 2,800.6 3,297.4 0.1518 0.1524 0.1537 71.61 2023-06-08
12 362 04QCB76G59403JD5H0000618 314.82 2,802.1 2,796.2 3,297.2 0.1552 0.1569 0.1553 71.57 2023-06-08
13 426 04QCB76G55703JD5G0004638 314.83 2,795.4 2,788.2 3,297.2 0.1538 0.1575 0.1526 71.50 2023-06-09
14 437 04QCB76G41103JD5G0009391 314.84 2,804.7 2,797.4 3,297.3 0.1529 0.1533 0.1509 71.57 2023-06-09
15 479 04QCB76G55503JD5G0004897 314.82 2,799.1 2,789.1 3,297.7 0.1585 0.1564 0.1538 71.45 2023-06-09
16 507 04QCB76G55503JD5G0004066 314.83 2,804.5 2,795.3 3,297.8 0.1555 0.1534 0.1513 71.79 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup