Weekly Deals! Shop with Discounts.

Home

Contact Us

Downloads

Reseller Login

Aftersale&Forum

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H240520R1006
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-SR1-PC200 Standard Example: GPEV280H240927R1001
GP-SR1-PC200 Basic Example: GPCN280L240809R1001
GP-SR1-PC314 Premium Example: GPEV314H240921R1012
GP-SR3-PC100 Example: GPEV100H240930R1003
GP-LA12-280AH Premium Example: GDEV280H240307R1008
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H240401R1004 298.00 57.99 44.32 GP-RN200 BMS
GPHC280H240506R1206 293.00 57.05 41.27 GP-PC200 BMS
GPEV280H231019R1029 291.00 56.12 45.18 GP-PC200 BMS
GPHC280H240506R1008 294.00 56.83 41.49 GP-PC200 BMS
GPEV100H241022R1010 104.00 57.33 42.59 GP-PC100 BMS
GPEV280H240401R1001 306.00 58.00 41.82 GP-PC200 BMS
GPHC280H241116R2901 292.00 57.38 42.11 GP-PC200 BMS
GPEV280H240124R1012 302.00 57.99 43.66 GP-RN200 BMS
GPEV280H240905R1009 307.00 57.99 42.73 GP-RN200 BMS
GPEV314H241101R1005 326.00 57.72 41.58 GP-PC200 BMS
GPEV280H240923R1004 305.00 57.02 42.48 GP-PC200 BMS
GPHC280H240418R1004 295.00 57.90 41.87 GP-JK200 BMS
GPEV280H240616R1019 304.00 57.87 41.87 GP-PC200 BMS
GPEV280H240515R1009 306.00 57.99 41.34 GP-PC200 BMS
GPEV314H241101R1013 327.00 57.28 41.71 GP-PC200 BMS
GPEV280H240710R1003 304.00 57.78 41.56 GP-PC200 BMS
GPEV280H231019R1022 299.00 57.86 41.73 GP-PC200 BMS
GPEV280H231123R1005 302.00 58.00 42.08 GP-PC200 BMS
GPEV280H231019R1025 301.00 58.00 41.78 GP-PC200 BMS
GPHC280H240925R1201 293.00 57.45 41.22 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV100H241123R1001
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC100 BMS
Balancer: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE 100Ah
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 102.00 Ah (5.22 kWh)
Max Charge Voltage: 57.96 V
Min Discharge Voltage: 41.71 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPEV100H241123R1001 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ)
1 63 04QCB6CJ43900JE9R0009595 106.89 3,300.3 0.2572
2 102 04QCB6CJA6300JE9Y0012717 106.85 3,300.3 0.2489
3 107 04QCB6CJ42000JEA50000288 106.82 3,300.2 0.2540
4 193 04QCB6CJ54800JE9R0006768 106.46 3,300.7 0.2556
5 322 04QCB6CJA7900JE960008098 106.85 3,300.3 0.2535
6 323 04QCB6CJA0000JE970004194 106.85 3,300.2 0.2574
7 328 04QCB6CJA0100JE980000677 106.63 3,300.5 0.2613
8 340 04QCB6CJA0000JE970011200 106.75 3,300.4 0.2565
9 343 04QCB6CJA0000JE970012425 106.47 3,300.4 0.2610
10 347 04QCB6CJA0100JE980000683 106.63 3,300.3 0.2587
11 351 04QCB6CJA0000JE970012430 106.37 3,300.4 0.2561
12 358 04QCB6CJA0000JE970012426 106.72 3,300.6 0.2571
13 365 04QCB6CJA0000JE970011188 106.80 3,300.4 0.2582
14 369 04QCB6CJA0000JE970012110 106.61 3,300.5 0.2638
15 373 04QCB6CJA0000JE970012820 106.90 3,300.4 0.2601
16 422 04QCB6CJ42000JEA50002580 106.69 3,300.1 0.2551
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.