SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPRP280L231012R1305 290.00 57.70 40.11 GP-PC200 BMS
GPEV280H231030R1007 300.00 57.99 45.55 GP-PC200 BMS
GPEV280L230602R1008 302.00 57.01 40.96 GP-PC200 BMS
GPHC280H240506R1008 294.00 56.83 41.49 GP-PC200 BMS
GPRP280L231012R1301 291.00 57.42 40.15 GP-PC200 BMS
GPEV280H240323R1002 298.00 58.00 42.23 GP-PC200 BMS
GPEV280L230801R2202 287.00 57.92 40.41 GP-PC200 BMS
GPEV280H231009R1003 298.00 57.99 42.39 GP-PC200 BMS
GPEV306H240514R1001 328.00 56.86 41.64 GP-JK200 BMS
GPRP280L231012R1005 292.00 57.61 40.27 GP-PC200 BMS
GPEV280H240105R1010 300.00 58.00 42.61 GP-PC200 BMS
GPEV280L230523R2401 302.00 56.79 41.94 GP-PC200 BMS
GPEV280H240105R1009 304.00 57.99 41.81 GP-PC200 BMS
GPHC280H240321R1501 305.00 58.00 42.64 GP-PC200 BMS
GPRP280L231127R2902 288.00 57.27 42.58 GP-PC200 BMS
GPEV280H230625R1023 305.00 57.62 40.61 GP-PC200 BMS
GPRP280L231115R2102 289.00 57.95 42.01 GP-PC200 BMS
GPEV280H231030R1004 299.00 57.26 41.51 GP-PC200 BMS
GPEV280H230705R1019 306.00 57.40 40.52 GP-PC200 BMS
GPEV280H240401R1018 303.00 58.00 43.73 GP-RN200 BMS
Specification of The Battery

Pack SN:GPEV280H230625R1022
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: With Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.57 V
Min Discharge Voltage: 40.76 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 22 04QCB76G55503JD5F0000113 314.84 2,801.6 2,792.3 3,297.3 0.1558 0.1564 0.1569 71.55 2023-06-08
2 68 04QCB76G52203JD5F0002184 314.81 2,798.8 2,789.1 3,297.3 0.1533 0.1530 0.1515 71.52 2023-06-09
3 160 04QCB76G55703JD5G0001997 314.85 2,800.0 2,793.3 3,297.4 0.1538 0.1582 0.1586 71.49 2023-06-08
4 210 04QCB76G52503JD5F0001226 314.84 2,800.0 2,792.2 3,297.4 0.1556 0.1561 0.1574 71.71 2023-06-08
5 214 04QCB76G55703JD5G0004986 314.81 2,798.5 2,792.7 3,297.6 0.1548 0.1548 0.1579 71.49 2023-06-08
6 222 04QCB76G55703JD5G0000982 314.86 2,802.8 2,796.5 3,297.5 0.1562 0.1549 0.1567 71.49 2023-06-08
7 223 04QCB76G52503JD5F0000609 314.86 2,802.2 2,794.9 3,297.5 0.1541 0.1532 0.1574 71.52 2023-06-08
8 251 04QCB76G55703JD5G0001744 314.83 2,798.1 2,789.9 3,297.6 0.1567 0.1562 0.1562 71.48 2023-06-08
9 282 04QCB76G55703JD5G0003226 314.85 2,800.6 2,794.9 3,297.6 0.1567 0.1578 0.1565 71.51 2023-06-08
10 333 04QCB76G52503JD5F0003612 314.85 2,799.7 2,791.1 3,297.3 0.1550 0.1544 0.1558 71.58 2023-06-08
11 361 04QCB76G59403JD5H0002323 314.82 2,804.3 2,800.6 3,297.4 0.1518 0.1524 0.1537 71.61 2023-06-08
12 362 04QCB76G59403JD5H0000618 314.82 2,802.1 2,796.2 3,297.2 0.1552 0.1569 0.1553 71.57 2023-06-08
13 426 04QCB76G55703JD5G0004638 314.83 2,795.4 2,788.2 3,297.2 0.1538 0.1575 0.1526 71.50 2023-06-09
14 437 04QCB76G41103JD5G0009391 314.84 2,804.7 2,797.4 3,297.3 0.1529 0.1533 0.1509 71.57 2023-06-09
15 479 04QCB76G55503JD5G0004897 314.82 2,799.1 2,789.1 3,297.7 0.1585 0.1564 0.1538 71.45 2023-06-09
16 507 04QCB76G55503JD5G0004066 314.83 2,804.5 2,795.3 3,297.8 0.1555 0.1534 0.1513 71.79 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.